Products >> Industrial RO Element >> Hydranautics RO Membrane Element
Hydranautics ESPA2-LD RO Membrane Element
The Hydranautics ESPA2-LD is a low fouling spiral-wound reverse osmosis (RO) membrane element comprising a composite polyamide material.Hydranautics ESPA2-LD RO Membrane Element Data sheet
Specified Performance*
|
Permeate Flow: |
10,000 gpd (37.9 m3/d) |
|
Salt Rejection: |
99.6% (99.5% minimum) |
|
Test Conditions: |
1500 ppm NaCl solution |
|
|
150 psig (1.03 MPa) Applied Pressure |
|
|
77℉ (25℃) Operating Temperature |
|
|
15% Permeate Recovery |
|
|
6.5 - 7.0 pH Range |
General Product Description**
|
Configuration: |
Low Fouling Spiral Wound |
|
Membrane Polymer: |
Composite Polyamide |
|
Membrane Active Area: |
400 ft2 (37.2 m2) |
|
Feed Spacer: |
34 mil (0.86 mm) |
Dimensions
|
A, inches(mm) |
B, inches(mm) |
C, inches(mm) |
|
40.0 (1016) |
7.89 (200) |
1.125 (28.6) |
Core tube extension = 1.05" (26.7 mm)
Product Use and Restrictions^
|
Maximum Applied Pressure |
600 psig (4.14 MPa) |
|
Maximum Chlorine Concentration |
< 0.1 ppm |
|
Maximum Operating Temperature |
113℉ (45℃) |
|
pH Range, Continuous (Cleaning) |
2-10.6 (1-12) |
|
Maximum Feedwater Turbidity |
1.0 NTU |
|
Maximum Feedwater SDI (15 mins) |
5.0 |
|
Maximum Feed Flow |
85 gpm (19.3 m3/h) |
|
Minimum Brine Flow |
12 gpm (2.7 m3/h) |
|
Maximum Pressure Drop for Each Element |
15 psi (0.10 MPa) |
Notice:
If you and your customer accept economical & quick-delivery equivalent of similar or better performance with same warranty, kindly send us an inquiry now.
Products Category
Contact Us
Name: International Sales Dept.
Tel: +86-27-8673 0002
Fax: +86-27-8732 0476
E-mail: inquiry@tanaltech.com
Add: 9th Floor, Jinhe Center, No. 191 Xudong Avenue, Hongshan District, Wuhan, Hubei, 430077, China