Check and select the suitable membranes for water and wastewater treatment projects.
Wuhan Tanal Industrial Co., Ltd.

Products >> Hollow Fiber UF Membrane >> DuPont UF Membrane Module

  • DuPont IntegraTec L10N
DuPont IntegraTec L10N

DuPont IntegraTec L10N

DuPont IntegraTec L10N Ultrafiltration Membrane

DuPont IntegraTec Pressurised modules L10N are used for a wide range of applications.

Module SpecificationsDuPont InergaTec L10N Ultrafiltation Membrane Dimension

Parameter

Details

Part Numbers

Single Module Pack (includes 4 fitted EPDM O-Rings and 7 gm Food Grade Silicone Grease Sachet):
SAP: 00012038343
Legacy: W3T310440-120406

Module Operating Process

Pressurized Ultrafiltration

Typical Applications

General Applications

Membrane Type

Hollow Fiber

Filtration Flow Direction

Outside to Inside

Backwash Type

Air Scour with Liquid Backwash

Membrane Material

PVDF (Polyvinylidene Fluoride)

Other Wetted Module Components

Polyurethane, Polyethylene, Polyamide, EPDM

Nominal Membrane Pore Size

0.04 μm

Nominal Membrane Area

21.1 m2 / 227 ft2

Nominal Module Length (Overall)

1157 mm / 45.5 in

Nominal Module Diameter (Overall)

119 mm / 4.7 in

Approximate Module Mass

7.5 kg / 16 lb

Potable Water Certification Note i

NSF/ANSI/CAN 61
Drinking Water System Components
– Health Effects

Operating Specifications

Parameter

Details

Operating Temperature Range

> 0 to 40 °C / > 32 to 104 °F (Must not be exposed to freezing conditions)

Temperature Range for Transportation and Storage

Preferred range 5 to 25 °C / 41 to 77 °F
Allowable range > 0 to 40 °C / > 32 to 104 °F
(shipment/storage in a temperature controlled container (or reefer) at 20 °C / 68 °F recommended).
Modules must not be exposed to freezing conditions and must remain moist at all times.

Typical Feed pH Range

6.0 – 9.0 pH Note ii

Allowable pH Range for Cleaning

2.0 – 10.5 pH typical Note iii

Typical Maximum Recommended Trans-Membrane Pressure (TMP) in Filtration (Pressurized Systems)

140 kPa / 20 psi Note iv

Maximum Allowable TMP at any time

± 150 kPa / ± 22 psi

Typical chlorine concentration during cleaning (MW or CIP)

50 – 200 mg/L @ 25 °C / 50 – 200 ppm @ 77 °F Note v

Maximum chlorine concentration during cleaning

1000 mg/L @ 25 °C / 1000 ppm @ 77 °F Note v

Maximum exposure to chlorine in feed or during storage

< 1 mg/L average, < 5 mg/L maximum, pH > 6.0
< 1 ppm average, < 5 ppm maximum, pH > 6.0 Note v

Maximum total chlorine exposure

1,000,000 mg.h/L @ 25 °C / 1,000,000 ppm.h @ 77 °F Note v

Maximum exposure to chloramines in feed or during storage

< 2.5 mg/L average, < 5 mg/L maximum, pH > 6.5
< 2.5 ppm average, < 5 ppm maximum, pH > 6.5 500,000 mg.h/L / 500,000 ppm.h
Note v

Notes:

i. NSF refers to NSF International formerly known as the National Sanitation Foundation. ANSI is a trademark of the American National Standards Institute.

ii. Exposure to chloramines is not recommended in feeds below 6.5 pH.

iii. Initial flushing of new modules followed by a cleaning cycle is recommended prior to use. Please refer to MEMCOR technical bulletin "Guidelines for flushing new MEMCOR® ‘N’ Series Modules” for further details.

iv. Maximum recommended filtration TMP for a particular application is usually feed dependent. The actual recommended value may vary from that shown.

v. Please consult DuPont Water Solutions for additional guidance on exposure limits and for operation at different temperatures.

From 45-D03411-en, Rev 12, Feb 2023

Notice:
If your customer insists existing brand, please contact DuPont or its distributors.
If you and your customer accept economical & quick-delivery equivalent of similar or better performance with same warranty, kindly send us an inquiry now.

Previous Product:DuPont MEMCOR L20N Next Product:DuPont MEMCOR L0V
WechatClose
Wechat
WhatsappClose
Whatsapp