Check and select the suitable membranes for water and wastewater treatment projects.
Wuhan Tanal Industrial Co., Ltd.

Products >> Hollow Fiber UF Membrane >> DuPont UF Membrane Module

  • DuPont MEMCOR L20N
DuPont MEMCOR L20N

DuPont MEMCOR L20N

DuPont MEMCOR L20N Ultrafiltration Membrane

DuPont MEMCOR Pressurised modules L20N are used for a wide range of applications.

Module SpecificationsDuPont MEMCOR L20N Ultrafiltation Membrane Dimension

Parameter

Details

Module Operating Process

Pressurized Ultrafiltration

Typical Applications

General Applications

Membrane Type

Hollow Fiber

Filtration Flow Direction

Outside to Inside

Backwash Type

Air Scour with Liquid Backwash

Membrane Material

PVDF (Polyvinylidene Fluoride)

Other Wetted Module Components

Polyurethane, FRP, Polyamide, EPDM

Nominal Membrane Pore Size

0.04 μm

Nominal Membrane Area

34.8 m2

Nominal Module Length (Overall)

1800 mm

Nominal Module Diameter (Overall)

119 mm

Approximate Module Mass

12.0 kg

Operating Specifications

Parameter

Details

Operating Temperature Range

> 0 to 35 °C (Must not be exposed to freezing conditions)

Temperature Range for Transportation and Storage

Preferred range 5 to 25 °C
Allowable range > 0 to 35 °C
(shipment/storage in a temperature controlled container (or reefer) at 20 °C recommended). Modules must not be exposed to freezing conditions and must remain moist at all times.

Typical Feed pH Range

6.0 – 9.0 pH Note i

Allowable pH Range for Cleaning

2.0 – 14.0 pH typical Note ii

Typical Maximum Recommended Trans-Membrane Pressure (TMP) in Filtration (Pressurized Systems)

140 kPa Note iii

Maximum Allowable TMP at any time

± 150 kPa / @ ≤30℃

± 120kPa / @ >30℃

Typical chlorine concentration during cleaning (MW or CIP)

50 – 200 mg/L @ 25 °C Note IV 

Maximum chlorine concentration during cleaning

1,000 mg/L @ 25 °C Note IV 

Maximum total chlorine exposure

500,000 mg.h/L @ 25 °C Note IV 

Maximum exposure to chlorine in feed or during storage

< 1 mg/L average, < 5 mg/L maximum, pH > 6.5 @ 25℃, 100,000 mg.h/L @ 25℃ Note IV

Maximum exposure to chloramines in feed or during storage

< 2.5 mg/L average, < 5 mg/L maximum, pH > 6.5 @25℃, 150,000 mg.h/L @ 25℃ Note IV

Notes:
i. Exposure to chloramines is not recommended in feeds below 6.5 pH.
ii. Allowed to reach ph 10.5 for a short period of time during cleaning.
iii. The maximum allowable transmembrane pressure difference is affected by many factors, including atmospheric pressure, membrane module immersion depth, and produced water pump cavitation margin requirements, etc., and the actual value may be slightly different from the above values.
iv. Please consult DuPont for chemical tolerance values and the effect of temperature on them.

Notice:
If your customer insists existing brand, please contact DuPont or its distributors.
If you and your customer accept economical & quick-delivery equivalent of similar or better performance with same warranty, kindly send us an inquiry now.

Previous Product:DuPont MEMCOR L40N Next Product:DuPont IntegraTec L10N