Check and select the suitable membranes for water and wastewater treatment projects.
Wuhan Tanal Industrial Co., Ltd.

Products >> Hollow Fiber UF Membrane >> DuPont UF Membrane Module

  • DuPont MEMCOR L40N
DuPont MEMCOR L40N

DuPont MEMCOR L40N

DuPont MEMCOR L40N Ultrafiltration Membrane

DuPont MEMCOR Pressurised modules L40N are used for a wide range of applications.
DuPont MEMCOR L40N Ultrafiltration Membrane Product Data Sheet

Module SpecificationsDuPont MEMCOR L40N Ultrafiltation Membrane Dimension

Parameter

Details

Module Operating Process

Pressurized Ultrafiltration

Typical Applications

General Applications

Membrane Type

Hollow Fiber

Filtration Flow Direction

Outside to Inside

Backwash Type

Air Scour with Liquid Backwash

Membrane Material

PVDF (Polyvinylidene Fluoride)

Other Wetted Module Components

Polyurethane, Polyethylene, Polyamide, EPDM

Nominal Membrane Pore Size

0.04 μm

Nominal Membrane Area

67.0 m2

Nominal Module Length (Overall)

1800 mm

Nominal Module Diameter (Overall)

182 mm

Approximate Module Mass

22.0 kg

Operating Specifications

Parameter

Details

Operating Temperature Range

> 0 to 35 °C (Must not be exposed to freezing conditions)

Temperature Range for Transportation and Storage

Preferred range 5 to 25 °C
Allowable range > 0 to 40 °C
(shipment/storage in a temperature controlled container (or reefer) at 20 °C recommended). Modules must not be exposed to freezing conditions and must remain moist at all times.

Typical Feed pH Range

6.0 – 9.0 Note i

Allowable pH Range for Cleaning

2.0 – 10.0 Note ii

Typical Maximum Recommended Trans-Membrane Pressure (TMP) in Filtration (Pressurized Systems)

140 kPa Note iii

Maximum Allowable TMP at any time

± 150 kPa / @ ≤30℃

± 120kPa / @ >30℃

Typical chlorine concentration during cleaning (MW or CIP)

50 – 200 mg/L @ 25 °C Note IV 

Maximum chlorine concentration during cleaning

1,000 mg/L @ 25 °C Note IV

Maximum total exposure to chlorine during cleaning

1,000,000 mg.h/L @ 25 °C Note IV 

Maximum exposure to chlorine in feed or during storage

< 1 mg/L average, < 5 mg/L maximum, pH > 6.5 @ 25℃, 100,000 mg.h/L @ 25℃ Note IV

Maximum exposure to chloramines in feed or during storage

< 2.5 mg/L average, < 5 mg/L maximum, pH > 6.5 @ 25℃, 150,000 mg.h/L @ 25℃ Note IV

Notes:
i. Exposure to chlorine or chloramines is not recommended in feeds below 6.5 pH.
ii. Occasional brief exposure during chlorine cleans to pH 10.5 is acceptable.
iii. Maximum recommended filtration TMP for a particular application is usually feed dependent. The actual recommended value may vary from that shown.
iv. Please consult Evoqua Water Technologies for additional guidance on exposure limits and for operation at different temperatures..

From MC-L40N-MODULE-AU-PS-A4-0115


Notice:
If your customer insists existing brand, please contact DuPont or its distributors.
If you and your customer accept economical & quick-delivery equivalent of similar or better performance with same warranty, kindly send us an inquiry now.

Previous Product:DuPont Inge dizzer XL 0.9 MB 36 WR Next Product:DuPont MEMCOR L20N