Check and select the suitable membranes for water and wastewater treatment projects.
Wuhan Tanal Industrial Co., Ltd.

Products >> Hollow Fiber UF Membrane >> DuPont UF Membrane Module

  • Siemens UF Membrane L40N
Siemens UF Membrane L40N

Siemens UF Membrane L40N

Siemens UF Membrane L40N Ultrafiltration Membrane

Siemens UF Membrane L40N are used for a wide range of applications.
Siemens UF Membrane L40N Ultrafiltration Membrane Product Data Sheet

Module SpecificationsSiemens UF Membrane L40N Ultrafiltation Membrane Dimension

Parameter

Details

Module Operating Process

Pressurized Ultrafiltration

Typical Applications

General Applications

Membrane Type

Hollow Fiber

Filtration Flow Direction

Outside to Inside

Backwash Type

Air Scour with Liquid Backwash

Membrane Material

PVDF (Polyvinylidene Fluoride)

Other Wetted Module Components

Polyurethane, Polyethylene, Polyamide, EPDM

Nominal Membrane Pore Size

0.04 μm

Nominal Membrane Area

67.0m2

Nominal Module Length (Overall)

1800mm

Nominal Module Diameter (Overall)

182mm

Approximate Module Mass

22.0kg

Operating Specifications

Parameter

Details

Operating Temperature Range

> 0 to 35°C (Must not be exposed to freezing conditions)

Temperature Range for Transportation and Storage

Preferred range 5 to 25 °C
Allowable range > 0 to 40°C
(shipment/storage in a temperature controlled container (or reefer) at 20 °C recommended). Modules must not be exposed to freezing conditions and must remain moist at all times.

Typical Feed pH Range

6.0 – 9.0 Note i

Allowable pH Range for Cleaning

2.0 – 10.0Note ii

Typical Maximum Recommended Trans-Membrane Pressure (TMP) in Filtration (Pressurized Systems)

140 kPa Note iii

Maximum Allowable TMP at any time

± 150 kPa / @ ≤30℃

± 120kPa / @ >30℃

Typical chlorine concentration during cleaning (MW or CIP)

50 – 200 mg/L @ 25 °C Note IV

Maximum chlorine concentration during cleaning

1,000 mg/L @ 25 °C Note IV

Maximum total exposure to chlorine during cleaning

1,000,000 mg.h/L @ 25 °C Note IV

Maximum exposure to chlorine in feed or during storage

< 1 mg/L average, < 5 mg/L maximum, pH > 6.5@ 25℃, 100,000 mg.h/L @ 25℃ Note IV

Maximum exposure to chloramines in feed or during storage

< 2.5 mg/L average, < 5 mg/L maximum, pH > 6.5@ 25℃, 150,000 mg.h/L@ 25℃Note IV

Notes:
i. Exposure to chlorine or chloramines is not recommended in feeds below 6.5 pH.
ii. Occasional brief exposure during chlorine cleans to pH 10.5 is acceptable.
iii. Maximum recommended filtration TMP for a particular application is usually feed dependent. The actual recommended value may vary from that shown.
iv. Please consult Evoqua Water Technologies for additional guidance on exposure limits and for operation at different temperatures..

From MC-L40N-MODULE-AU-PS-A4-0115


Notice:
If your customer insists existing brand, please contact DuPont or its distributors.
If you and your customer accept economical & quick-delivery equivalent of similar or better performance with same warranty, kindly send us an inquiry now.

WechatClose
Wechat
WhatsappClose
Whatsapp