Check and select the suitable membranes for water and wastewater treatment projects.
Wuhan Tanal Industrial Co., Ltd.

Products >> Hollow Fiber UF Membrane >> DuPont DOW UF Membrane Module

  • DuPont DOW UF Membrane IPD-51XP
DuPont DOW UF Membrane IPD-51XP

DuPont DOW UF Membrane IPD-51XP

Features

The DuPont DOW UF Membrane modules IPD-51XP with XP fiber are made from high permeability, high mechanical strength, hollow fiber PVDF membranes. The modules provide excellent performance, industry leading membrane area with low energy and chemical consumption. The IPD-51XP modules have the following general properties and characteristics:
  • Up to 35% higher permeability than previous generation modules improving operating efficiencies and productivity
  • 0.03 µm nominal pore diameter for removal of bacteria, viruses, and particulates including colloids to protect downstream processes such as RO
  • PVDF polymeric hollow fibers for high mechanical strength with excellent chemical resistance providing long membrane life and reliable operation
  • Outside-In flow configuration allowing a wide range of solids in the feed water minimizing the need for pretreatment processes and reducing the backwash volume compared to Inside-Out configurations Innovative end-caps enable direct coupling of modules, eliminating the need for piping manifolds
These modules are an excellent choice for systems requiring a small footprint. The IPD-51XP module is shorter in height and is suitable for applications where height is a constraint while maximizing productivity and efficiency with high permeability fibers.
The
DuPont™ DOW™ UF Membrane modules IPD-51XP can be used for a wide variety of treatment applications, such as groundwater, surface water, seawater, industrial wastewaters and municipal wastewater polishing.

Product Specifications

 

 

Membrane area

Weight

(empty/water filled)

Hold-Up Volume

Model

Type

 

m2

ft2

kg

lbs

liters

gallons

IPD-51XP


NSF/ANSI61and419

 

51

549

53/102

117/225

49

13

Figure 1
DOW™ Ultrafiltration Modules Model IPD-51XP Figure 1

Figure 2
DOW™ Ultrafiltration Modules Model IPD-51XP Figure 2

Dimensions

Length

Diameter

Width

Units

L

L1

L2

L3

D

W1

W2

SI (mm)

1988±3

1500

1689±3

1864±3

225

360

342

US (inch)

98.3±0.1

59.1

66.5±0.1

73.4±0.1

8.9

14.2

13.5

Operating Parameters

SI Units

US Units

Filtrate Flux (25ºC)

40 110 l/m2hr

24 65 gfd

Flow Range Per Module1

2.0 8.5 m3/hr

8.8 37.4 gpm

Temperature

1 40ºC

34 104ºF

Maximum Inlet Module Pressure (20ºC)

6.25 bar

90.65 psi

Maximum Inlet Module Pressure (40ºC)

4.75 bar

68.89 psi

Maximum Operating TMP

2.1 bar

30.5 psi

Maximum Operating Air Scour Flow

12 Nm3/hr

7.1 scfm

Maximum Backwash Pressure

2.5 bar

36 psi

Operating pH

2 -11

Maximum NaOCl

2000 mg/L

Maximum Particle Size

300 μm

Flow Configuration

Outside-in

Expected Filtrate Turbidity

0.1 NTU

Expected Filtrate SDI

2.5

Important information

Proper start-up of an ultrafiltration system is essential to prepare the membranes for operating service and to prevent membrane damage. Following the proper start-up sequence also helps ensure that system operating parameters conform to design specifications so that system water quality and productivity goals can be achieved. Before initiating system start-up procedures, membrane pretreatment, installation of the membrane modules, instrument calibration and other system checks should be completed. Please refer to the Ultrafiltration Technical Manual.

Operation guidelines

Avoid any abrupt pressure variations during start-up, shutdown, cleaning or other sequences to prevent possible membrane damage. Flush the ultrafiltration system to remove shipping solution prior to start-up. Remove residual air from the system prior to start-up. Manually start the equipment. Depending on the application, filtrate obtained from initial operations should be discarded.
Please refer to the Ultrafiltration Technical Manual.

General information

If operating limits and guidelines given in this bulletin are not strictly followed, the limited warranty will be null and void.
To control biological growth during extended system shutdowns, it is recommended that storage solution be injected into the membrane modules.
Please refer to the Ultrafiltration Technical Manual and Technical Service Bulletins.
Regulatory note
NSF/ANSI 61 and 419 certified drinking water modules require specific conditioning procedures prior to producing potable water. Please refer to the Ultrafiltration Technical Manual flushing section for specific procedures. Drinking water modules may be subjected to additional regulatory restrictions in some countries. Please check local regulatory guidelines and application status before use and sales.

Version: Form No. 45-D01160-en, Rev. 6

Notice:
If your customer insists existing brand, please contact DuPont or its distributors.
If you and your customer accept economical & quick-delivery equivalent of similar or better performance with same warranty, kindly send us an inquiry now.

WechatClose
Wechat
WhatsappClose
Whatsapp