Check and select the suitable membranes for water and wastewater treatment projects.
Wuhan Tanal Industrial Co., Ltd.

Products >> Hollow Fiber UF Membrane >> Pentair X-Flow UF Membrane Module

  • Pentair X-FLOW XF75 Membrane Element
Pentair X-FLOW XF75 Membrane Element

Pentair X-FLOW XF75 Membrane Element

General Information

Pentair X-FLOW XF75 is an ultrafiltration, used for the production of process and potable water from surface water, for wastewater polishing and reuse, in the pre-treatment of large SWRO plants, and in large-scale drinking water production. The XF75 module can be utilized in Pentair’s unique solutions Aquaflex and X-Line. 

The XF75 membrane element has the following general properties and characteristics:

  • Hydrophilic membrane composed of a blend of polyvinylpyrrolidone and polyethersulfone
  • A nominal pore size of 20 nm
  • Structure asymmetric/microporous
  • High performance and a very good anti fouling behaviour
  • Typical permeate quality SDI<3, turbidity <0,1 NTU
  • Membrane filtration provides 99.9999% (LOG6) reduction of bacteria (Pseudomonas diminuta) and 99.99% (LOG 4) reduction of virus (MS2 colifages) by mechanical means. EPA Est. No. 090374-NLD-001
Pentair X-FLOW XF75 Membrane Element Product Data Sheet

Module Dimensions

Pentair X-Flow XF75 Ultrafiltration Membrane Dimension


 

Model


Feed connection D0

mm/inch


Module Length L0

mm/inch


Permeate connection 
d0

mm/inch


XF75


220.0 /8.66


1537.5 /60.52


51.6 /2.03

 Physical and Operating Specifications


Specifications


Parameters


Model


XF75


Membrane area (m²/ft²)


75 /807


Membrane diameter (mm/mil)


0.72 /28.3


Housing material


PVC white


Flow distributor material


PVC


Potting material


PU resin


Membrane material


PES/PVP


Max. trans-membrane pressure Filtration


100 kPa /14.5 psi


Max. trans-membrane pressure Backwash


200 kPa /29 psi


Temp. range


0-40℃ /32-104°F


pH-during filtration


2-12


pH-during cleaning


1-13


Dry weight of membrane element


ca. 34 kg /75 lbs


Wet weight filled with water


ca. 66 kg/145 lbs


Crossflow flow rate
(superficial velocity)


49.9 × v m3/h

219.7 × v gpm


Pressure-drop across module at 0.2 m/s


19 kPa /2.8 psi


Pressure-drop across module at 0.5 m/s


47.7 kPa /6.9 psi

(v) in m/s [ft/s] 
Storage

New membrane modules can be stored as supplied in the original packaging. The membrane modules contain an aqueous preservation solution of glycerine (20wt%) and sodium metabisulfite (1wt%). Membrane modules should be stored in a dry, normally ventilated place, away from sources of heat ignition and direct sunlight. Storage temperature should be between 0 and 40 °C

From ENG V2620

Notice:
If your customer insists existing brand, please contact Pentair or its distributors.
If you and your customer accept economical & quick-delivery equivalent of similar or better performance with same warranty, kindly send us an inquiry now.
WechatClose
Wechat
WhatsappClose
Whatsapp