Check and select the suitable membranes for water and wastewater treatment projects.
Wuhan Tanal Industrial Co., Ltd.

Products >> Hollow Fiber UF Membrane >> DuPont DOW UF Membrane Module

  • DuPont DOW UF Membrane IP-51
DuPont DOW UF Membrane IP-51

DuPont DOW UF Membrane IP-51

Features

The DuPont™ DOW™ UF Membrane modules IP-51 are made from high strength, hollow fiber membranes engineered to reduce design and fabrication requirements with features and benefits including:
  • 0.03 micronporesize for removal of bacteria, viruses and particulates, a 6 log removal of bacteria, a 2.5 log removal on viruses, and a <2.5 SDI guarantee with proper operation
  • PVDF fibers which offer strength, chemical and fouling resistance; which allows for extended membrane life and consistent long-term performance
  • Outside-in flow configuration allows higher TSS feed waters, while maintaining reliable system performance and high quality filtrate
  • Innovative end-caps enable direct coupling of modules, eliminating the need for piping manifolds
These modules are an ideal choice for systems requiring a small footprint. The IP-51 modules are shorter in height and are suitable for applications where there is a head spaceconstraint.
DuPont DOW ultrafiltration modules IP-51 can be used for a wide variety of treatment applications, such as groundwater, surface water, seawater, industrial and municipal wastewaters.

Product Specifications

 

 

Membrane area

Weight

(empty/water filled)

Hold-Up Volume

Model

Type

 

m2

ft2

kg

lbs

liters

gallons

IP-51


Industrial

 

51

549

53/102

117/225

49

13

Figure 1
DOW™ Ultrafiltration Modules Model IP-51 Figure 1

Figure 2
DOW™ Ultrafiltration Modules Model IP-51 Figure 2

 

Dimensions

Length

Diameter

Width

Units

L

L1

L2

L3

D

W1

W2

SI (mm)

1988

1500

1689

1864

225

360

342

US (inch)

78.3

59.1

66.5

73.4

8.9

14.2

13.5

Operating Parameters

SI units

US units

Filtrate Flux @ 25ºC

40-90 l/m2/ hr

24-53 gfd

Flow range

2.0-6.9 m3/hr

8.8 – 30.4 gpm

Temperature

1-40ºC

34-104º F

Max. inlet module pressure (@ 20ºC)

6.25 bar

90.65 psi

Max. inlet module pressure (@ 40ºC)

4.75 bar

68.89 psi

Max Operating TMP

2.1 bar

30.5 psi

Max Operating Air Scour Flow

12 Nm3/hr

7.1 scfm

Max Backwash Pressure

2.5 bar

Operating pH

2 - 11

NaOCI (max.)

2,000 mg/L

Particle size (max.)

300 µm

Flow configuration

Outside in

Expected filtrate turbidity

≤0.1 NTU

Expected filtrate SDI

≤2.5

Important information

Proper start-up of an ultrafiltration system is essential to prepare the membranes for operating service and to prevent membrane damage. Following the proper start-up sequence also helps ensure that system operating parameters conform to design specifications so that system water quality and productivity goals can be achieved. Before initiating system start-up procedures, membrane pretreatment, installation of the membrane modules, instrument calibration and other system checks should be completed. Please refer to the Ultrafiltration Technical Manual.

Operation guidelines

Avoid any abrupt pressure variations during start-up, shutdown, cleaning or other sequences to prevent possible membrane damage. Flush the ultrafiltration system to remove shipping solution prior to start-up. Remove residual air from the system prior to start-up. Manually start the equipment. Depending on the application, filtrate obtained from initial operations should be discarded. Please refer to the Ultrafiltration Technical Manual.

General information

If operating limits and guidelines given in this bulletin are not strictly followed, the limited warranty will be null and void.
To control biological growth during extended system shutdowns, it is recommended that storage solution be injected into the membrane modules.
Regulatory note
NSF/ANSI 61and 419 certified drinking water modules require specific conditioning procedures prior to producing potable water. Please refer to the Ultrafiltration Technical Manual (Form No. 45-D00874-en) flushing section for specific procedures. Drinking water modules may be subjected to additional regulatory restrictions in some countries. Please check local regulatory guidelines and application status before use and sales.

Version: Form No.45-D01162-en, Rev. 5

Notice:
If your customer insists existing brand, please contact DuPont or its distributors.
If you and your customer accept economical & quick-delivery equivalent of similar or better performance with same warranty, kindly send us an inquiry now.