Features

The DuPont IntegraTec XP 77 IP modules are made from excellent permeability, high antifouling properties, XP™ Hydrophilic PVDF Fiber. The modules provide excellent performance, industry leading membrane area with low energy and chemical consumption and high filtration area to maximize productivity. The XP 77 IP modules have the following general properties and characteristics:
  • Proven XP™ Hydrophilic PVDF Fiber:
Superior fouling and chlorine resistance.
High colloidal particulate, bacteria, and virus log removal rate.
Excellent filtration permeability.
Easy cleaning and wettability.
  • Optimized Module Design:
Innovative end cap to direct coupling of modules in IP skids with simple assembly and scalability.
High active filtration area to maximize productivity.
High operation recovery with high air scouring tolerance.
Reduced chemical consumption with maintenance cleanings protocol.
Robust materials for long lifetime.
Easy installation and low maintenance.

The DuPont IntegraTec XP 77 IP module is higher in recovery with large size filtration.
The DuPont IntegraTec XP 77 IP can be used for a wide variety of treatment applications:

Municipal drinking water.

Industrial utility water.

Industrial wastewater reuse.

Municipal wastewater filtration.

RO pretreatment.

Product Specifications

         

Part No / GMID

Mode of Filtration

Type

Material

Pore Size

Operating Process

Other Wetted
Module Components


XP 77 IP


12091629


Out-In
Pressurized


Hollow
fiber


PVDF
(Polyvinylidene Fluoride)


0.03
μm


Dead-end


Polyurethane,
uPVC, EPDM, and ABS

 Figure 1

DuPont™ IntegraTec XP 77 IP Figure 1

Figure 2
DuPont™ IntegraTec XP 77 IP Figure 2

Properties

Membrane Area


W
eight

(shipping/empty/filled)


H
old-Up Volume(Clean-In-Place = CIP)

(Feed/Membrane Structure/Filtrate)

Product

m2

ft2

kg

lbs

liters

gallons

XP 77 IP

77

829

81/66/119

178/146/262

38/14/12

10.0/3.7/3.2


Dimensions

Units

Length

Diameter

Width

L

L1

L2

L3

D

W1

W2

SI (mm)

2,488 ± 3.0

2,000 ± 3.0

2,189 ± 3.0

2,364 ± 3.0

225

360

342

US (inch)

98.0 ± 0.1

78.7 ± 0.1

86.2 ± 0.1

93.1 ± 0.1

8.9

14.2

13.5






   
Operating Parameters


Operating Temperature Range


1
- 40 °C


34
- 104 °F


Operating
pH


2
- 11


Cleaning
pH


2
- 12


Typical
Filtration Trans-Membrane Pressure (TMP)


0.4
- 1.5 bar


5.8
- 21.8 psi


Typical
Backwash TMP


0.6
- 2.0 bar


8.7
- 29.0 psi


Backwash
Type


Air
scour with liquid backwash


Backwash
Flux


100
L/(m²h)


58.8
gfd


Backwash
Flow


7.7
m3h


34.0
gpm


Rate
of Pressure Change (Max)


0.5
bar/sec


7.3
psi/sec


Inlet
Pressure (Max)


6.25
bar (at 20 °C)


90.7
psi


Filtration
TMP (Max)


2.1
bar


30.5
psi


Backwash
TMP (Max)


2.5
bar


36
psi


Filtration
Flux (Max)


110
L/(m2h)


64.5
gfd


Filtration
Flow (Max)


8.5
m3h


37.4
gpm


Backwash
Flux (Max)


120
L/(m²h)


70.6
gfd


Particle
Size (Max)


300
μm


Exposure
NaOCl (Max)


1,500,000 ppm x h


Recommended
max. instantaneous exposure NaOCl



2,000
ppm

Operation guidelines
Avoid any abrupt pressure variations during start-up, operation, shutdown, cleaning or other sequences to prevent possible membrane damage. The maximum pressure change allowable is 0.5 bar/s.
Please refer to the latest version of the DuPont™ IntegraTec™ PVDF-UF Out-In P Series IntegraPac™ Rack Assembly Manual
General information
If operating limits and guidelines given in this document are not strictly followed, any warranty will be null and void.
To control biological growth during extended system shutdowns, storage solution has to be introduced into the membrane modules.
Regulatory note
Certified drinking water modules require specific conditioning procedures prior to producing potable water. For operating parameters, please refer to the DuPont™ IntegraTec™ P Series PVDF-UF OUT-In-Progress and Design Manual.
Drinking water modules may be subjected to additional regulatory restrictions in some countries. Please check local regulatory guidelines and application status before use.

Version: Form No . 45-D01160-en, Rev. 7

Notice:
If your customer insists existing brand, please contact DuPont or its distributors.
If you and your customer accept economical & quick-delivery equivalent of similar or better performance with same warranty, kindly send us an inquiry now.

Previous Product:DuPont IntegraTec XP 77 IP IG Next Product:DuPont IntegraTec XP 51 IP
WechatClose
Wechat
WhatsappClose
Whatsapp